{"product_id":"assurecheck-10hr-biological-indicator-st1010-25-vials-box-by-medicom","title":"AssureCheck™ 10HR Biological Indicator ST1010 + 25 vials\/box by Medicom","description":"\u003ch2 class=\"aaa\"\u003eAssureCheck™ 10HR\u003cspan\u003eBiological Indicator\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"main_desc\"\u003e\n\u003cp\u003eThese indicators help verify that the conditions for sterilization have been met. Designed for use with the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/medicom.com\/en_ca\/product\/assurecheck-dry-block-incubator\/\"\u003e\u003cstrong\u003eAssureCheck™ Dry Block Incubator\u003c\/strong\u003e\u003c\/a\u003e (sold separately).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccurate and efficient\u003c\/strong\u003e: Self-contained, easy-to-use design simplifies the monitoring process and supports compliance.\u003cbr\u003e\u003cstrong\u003eClear visual readout\u003c\/strong\u003e: Distinct color change ensures ease of interpretation.\u003cbr\u003e\u003cstrong\u003eVersatile\u003c\/strong\u003e: Compatible for use in all steam sterilizers.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cstrong\u003ePackaging Detail: \u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e25 units\/box, 6 boxes\/case\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        * {\n            box-sizing: border-box;\n        }\n\n        body {\n            margin: 0;\n            padding: 40px 20px;\n            font-family: Arial, Helvetica, sans-serif;\n            background: #f5f7fa;\n            color: #222;\n        }\n\n        .faq-container {\n            max-width: 1000px;\n            margin: 0 auto;\n        }\n\n        \/* HEADER *\/\n        .faq-title {\n            text-align: center;\n            margin-bottom: 35px;\n        }\n\n        .faq-title h1 {\n            margin: 0 0 10px;\n            color: #1b365d;\n            font-size: 32px;\n        }\n\n        .faq-title p {\n            margin: 0;\n            color: #666;\n            font-size: 16px;\n        }\n\n        \/* FAQ BOX *\/\n        .faq-item {\n            background: #ffffff;\n            border: 1px solid #dfe4ea;\n            border-radius: 8px;\n            margin-bottom: 12px;\n            overflow: hidden;\n            box-shadow: 0 2px 6px rgba(0, 0, 0, 0.04);\n        }\n\n        \/* QUESTION *\/\n        .faq-question {\n            width: 100%;\n            border: none;\n            background: #ffffff;\n            padding: 20px 60px 20px 20px;\n            text-align: left;\n            font-size: 17px;\n            font-weight: 600;\n            color: #1b365d;\n            cursor: pointer;\n            position: relative;\n            transition: background 0.2s ease;\n        }\n\n        .faq-question:hover {\n            background: #f7f9fc;\n        }\n\n        \/* PLUS \/ MINUS ICON *\/\n        .faq-question::after {\n            content: \"+\";\n            position: absolute;\n            right: 20px;\n            top: 50%;\n            transform: translateY(-50%);\n            font-size: 26px;\n            font-weight: 400;\n            color: #1b365d;\n        }\n\n        .faq-item.active .faq-question::after {\n            content: \"−\";\n        }\n\n        \/* ANSWER *\/\n        .faq-answer {\n            display: none;\n            padding: 0 20px 22px 20px;\n            border-top: 1px solid #edf0f3;\n            line-height: 1.7;\n            color: #444;\n            font-size: 15px;\n        }\n\n        .faq-item.active .faq-answer {\n            display: block;\n        }\n\n        \/* ANSWER LABEL *\/\n        .answer-label {\n            display: inline-block;\n            margin-top: 18px;\n            margin-bottom: 10px;\n            padding: 5px 10px;\n            background: #e8f1fb;\n            color: #1b365d;\n            border-radius: 4px;\n            font-weight: bold;\n            font-size: 13px;\n        }\n\n        .faq-answer p {\n            margin-top: 8px;\n            margin-bottom: 12px;\n        }\n\n        .faq-answer ul,\n        .faq-answer ol {\n            margin-top: 8px;\n            padding-left: 25px;\n        }\n\n        .faq-answer li {\n            margin-bottom: 7px;\n        }\n\n        .faq-answer strong {\n            color: #222;\n        }\n\n        \/* IMPORTANT BOX *\/\n        .important {\n            padding: 13px 15px;\n            margin-top: 15px;\n            background: #fff8e6;\n            border-left: 4px solid #e0a800;\n            border-radius: 4px;\n        }\n\n        \/* MOBILE *\/\n        @media (max-width: 600px) {\n\n            body {\n                padding: 20px 12px;\n            }\n\n            .faq-title h1 {\n                font-size: 25px;\n            }\n\n            .faq-title p {\n                font-size: 14px;\n            }\n\n            .faq-question {\n                font-size: 15px;\n                padding: 17px 45px 17px 15px;\n            }\n\n            .faq-answer {\n                padding: 0 15px 18px;\n                font-size: 14px;\n            }\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"faq-container\"\u003e\n\u003c!-- TITLE --\u003e\n\u003cdiv class=\"faq-title\"\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003cp\u003eAssureCheck™ 10HR Biological Indicator\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q1 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How often should biological monitoring (spore testing) be performed in a dental practice? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eIn Canada, CSA standards and most provincial infection prevention and control (IPAC) guidelines require biological monitoring (spore testing) \u003cstrong\u003edaily\u003c\/strong\u003e, and with each type of sterilization cycle used.\u003c\/p\u003e\n\u003cp\u003eRequirements may vary slightly depending on the province and practice setting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q2 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e In addition to routine testing, when should a spore test be performed? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eSpore tests should also be performed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAfter installing or relocating a sterilizer.\u003c\/li\u003e\n\u003cli\u003eFollowing sterilizer malfunctions or major repairs.\u003c\/li\u003e\n\u003cli\u003eAfter a failed sterilization cycle.\u003c\/li\u003e\n\u003cli\u003eWith every load containing implantable devices.\u003c\/li\u003e\n\u003cli\u003eWhen changing packaging materials, cassettes, or trays.\u003c\/li\u003e\n\u003cli\u003eAfter training new staff in instrument reprocessing.\u003c\/li\u003e\n\u003cli\u003eFollowing changes to sterilization procedures or load configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways follow applicable local infection-control requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q3 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Should a BI be run on a full or empty sterilizer chamber? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eFor routine testing, the BI should be placed in a \u003cstrong\u003estandard load\u003c\/strong\u003e to simulate normal operating conditions.\u003c\/p\u003e\n\u003cp\u003eFollow the sterilizer manufacturer's instructions and the applicable biological indicator instructions for use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q4 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What is the proper location for placing a BI in the sterilizer? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003ePlace the BI in the \u003cstrong\u003emost challenging area of the sterilizer chamber\u003c\/strong\u003e, where air removal and steam penetration are most difficult.\u003c\/p\u003e\n\u003cp\u003eFollow the sterilizer manufacturer's instructions for the recommended BI placement.\u003c\/p\u003e\n\u003cp\u003eMedicom recommends alternating the BI placement location periodically.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q5 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Can a BI be placed in a sterilization pouch? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn Canada, the BI must be placed inside a Process Challenge Device (PCD) or BI challenge test pack.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PCD or challenge test pack may be commercially purchased or assembled in-house using a pouch or cassette, according to the applicable instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q6 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How should test and control vials be labeled? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eLabel the vials with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDate\u003c\/li\u003e\n\u003cli\u003eSterilizer number or identifier\u003c\/li\u003e\n\u003cli\u003eLoad or cycle number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe control vial should be clearly identified as \u003cstrong\u003e\"CONTROL\"\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q7 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What is the function of a control vial? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eThe control vial confirms that the spores in the biological indicator are viable and that the incubation conditions are capable of supporting growth.\u003c\/p\u003e\n\u003cp\u003eThe control vial is \u003cstrong\u003enot processed through the sterilizer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q8 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e When is a control vial required? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eA control vial should be used with \u003cstrong\u003eevery BI test\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe control should come from the same BI lot as the test vial and should be incubated under the same conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q9 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Can one control vial be used for multiple sterilizers or test vials? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eYes, when the test vials are processed at approximately the same time and will be incubated together.\u003c\/p\u003e\n\u003cp\u003eIf tests are performed at different times and incubated separately, a \u003cstrong\u003enew control vial\u003c\/strong\u003e should be used.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q10 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What types of sterilizers are compatible with the Medicom AssureCheck™ 10H BI? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eThe AssureCheck™ 10H BI is compatible with steam sterilizers, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGravity displacement sterilizers\u003c\/li\u003e\n\u003cli\u003ePre-vacuum \/ dynamic air removal sterilizers\u003c\/li\u003e\n\u003cli\u003eSFPP (steam-flush pressure-pulse) sterilizers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q11 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What type of incubators are compatible with the Medicom AssureCheck™ 10HR BIs? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eThe AssureCheck™ 10HR BI is validated for use with the \u003cstrong\u003eAssureCheck™ Dry Block Incubator\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIf another incubator is used, it must reliably maintain \u003cstrong\u003e60°C ±2°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv class=\"important\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not modify or attempt to recalibrate the incubator unless specifically authorized by the manufacturer.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q12 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e When should BI vials be crushed and incubated? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eBI vials should ideally be crushed and incubated within \u003cstrong\u003e2 hours\u003c\/strong\u003e after the sterilization cycle ends.\u003c\/p\u003e\n\u003cp\u003eWait until all test vials from the same test batch are ready so that they can be incubated together with the control vial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q13 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How long should a BI vial cool before crushing? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eAllow the processed BI vial to cool for at least \u003cstrong\u003e10 minutes\u003c\/strong\u003e before crushing.\u003c\/p\u003e\n\u003cp\u003eCooling reduces internal pressure and helps prevent breakage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q14 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Should test and control vials be incubated together? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e The control vial should be incubated at the same time and under the same conditions as the test vials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q15 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What is the correct incubation temperature for the Medicom AssureCheck™ 10HR BI? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eThe correct incubation temperature is \u003cstrong\u003e60°C ±2°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q16 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What is the required incubation time to ensure valid results? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eIncubate the AssureCheck™ 10HR BI for the full \u003cstrong\u003e10-hour incubation period\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q17 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e If the BI changes color after a few hours, is full incubation still required? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e Even if a color change appears after only a few hours, the BI must complete the full \u003cstrong\u003e10-hour incubation period\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q18 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How long should the incubator be plugged in before use? Why does the LED flash? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eAllow the incubator to warm up for at least \u003cstrong\u003e20 minutes\u003c\/strong\u003e before use, according to the applicable instructions.\u003c\/p\u003e\n\u003cp\u003eA flashing LED generally indicates that the incubator is still warming up.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q19 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What color change occurs in the BI when sterilization fails? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eWhen sterilization fails, the BI changes from \u003cstrong\u003epurple to yellow\u003c\/strong\u003e after incubation.\u003c\/p\u003e\n\u003cp\u003eThe yellow color indicates microbial growth.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q20 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What if the control vial remains purple after incubation? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eIf the control vial remains \u003cstrong\u003epurple\u003c\/strong\u003e, the test is considered \u003cstrong\u003einvalid\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis may indicate that the spores were not viable or that the incubation conditions were not appropriate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q21 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Why does the control vial appear brownish rather than yellow following incubation? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eA brownish or bourbon-colored appearance may indicate \u003cstrong\u003epartial growth or an incubation issue\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIf the control result is unclear, the test should not be considered valid until the manufacturer's troubleshooting instructions have been followed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q22 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Why does the vial liquid appear cloudy after incubation? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eCloudiness may occur as a result of microbial growth or contamination.\u003c\/p\u003e\n\u003cp\u003eCloudiness alone should not be used to determine the final result. Evaluate the color change and control result according to the manufacturer's instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q23 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How can the test and control BI vials be differentiated after incubation? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eClearly label the vials before incubation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl vial:\u003c\/strong\u003e should show the expected positive growth result.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest vial:\u003c\/strong\u003e remains purple when sterilization is successful.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest vial:\u003c\/strong\u003e turns yellow when sterilization fails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q24 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What should be done after an initial BI test failure? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eIf an initial BI test fails:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eStop using the sterilizer.\u003c\/li\u003e\n\u003cli\u003eNotify the Infection Control Lead or responsible person.\u003c\/li\u003e\n\u003cli\u003eQuarantine instruments from the failed load and affected loads as appropriate.\u003c\/li\u003e\n\u003cli\u003eReview sterilizer operation, loading, packaging, and processing procedures.\u003c\/li\u003e\n\u003cli\u003eCorrect any identified problems.\u003c\/li\u003e\n\u003cli\u003eReprocess the instruments using the appropriate sterilization cycle.\u003c\/li\u003e\n\u003cli\u003eRepeat testing using physical, chemical, and biological indicators.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q25 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What should be done after a consecutive BI test failure? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003col\u003e\n\u003cli\u003eRemove the sterilizer from service.\u003c\/li\u003e\n\u003cli\u003eRecall instruments processed since the last confirmed negative BI result, according to applicable procedures.\u003c\/li\u003e\n\u003cli\u003eReprocess instruments using a functioning alternate sterilizer.\u003c\/li\u003e\n\u003cli\u003eHave the sterilizer inspected and repaired by a qualified technician.\u003c\/li\u003e\n\u003cli\u003eAfter repair, perform three consecutive standard-load cycles.\u003c\/li\u003e\n\u003cli\u003eInclude a new BI and chemical indicators in each cycle.\u003c\/li\u003e\n\u003cli\u003eThe sterilizer should only return to service after all three BI tests pass.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q26 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Does a passing BI result guarantee that all instruments are sterile? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA passing BI is an important part of sterilization monitoring, but it does not guarantee that every instrument in the load is sterile.\u003c\/p\u003e\n\u003cp\u003eProper cleaning, packaging, loading, sterilizer operation, and mechanical and chemical monitoring are also essential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q27 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e What documentation is required for biological monitoring? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eMaintain records of each biological monitoring test, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDate and time\u003c\/li\u003e\n\u003cli\u003eSterilizer identification\u003c\/li\u003e\n\u003cli\u003eBI lot number\u003c\/li\u003e\n\u003cli\u003eTest result\u003c\/li\u003e\n\u003cli\u003eControl result\u003c\/li\u003e\n\u003cli\u003eName or identification of the person performing the test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMedicom recommends retaining these records for at least \u003cstrong\u003e3 years\u003c\/strong\u003e, or according to applicable local regulatory requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q28 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How should used\/yellow vials be disposed of? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eVials that remain purple after incubation can be disposed of according to applicable waste procedures.\u003c\/p\u003e\n\u003cp\u003eVials that show growth and become \u003cstrong\u003eyellow\u003c\/strong\u003e should be placed in a sterilization pouch and reprocessed in the sterilizer according to the manufacturer's instructions before disposal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q29 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e Are the contents of the BI vials hazardous? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eNo. The spores used in the BI are \u003cstrong\u003enon-pathogenic\u003c\/strong\u003e and classified as \u003cstrong\u003eBiosafety Level 1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eStandard precautions should nevertheless be followed when handling biological indicators.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ===================================================== --\u003e \u003c!-- Q30 --\u003e \u003c!-- ===================================================== --\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cbutton class=\"faq-question\"\u003e How should the box of BIs be stored? \u003c\/button\u003e\n\u003cdiv class=\"faq-answer\"\u003e\n\u003cp\u003eStore the biological indicators in a \u003cstrong\u003ecool, dry place\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eKeep the BIs away from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect sunlight\u003c\/li\u003e\n\u003cli\u003eExcessive heat\u003c\/li\u003e\n\u003cli\u003eMoisture\u003c\/li\u003e\n\u003cli\u003eChemicals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways follow the storage conditions specified on the product packaging and Instructions for Use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ========================================================= --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- JAVASCRIPT --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- ========================================================= --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Medicom®","offers":[{"title":"Default Title","offer_id":52790290579743,"sku":null,"price":148.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/3577\/files\/AssureCheck_10HR_Biological_Indicator_ST1010_25_vials_box_by_Medicom.png?v=1787080650","url":"https:\/\/udscanada.com\/products\/assurecheck-10hr-biological-indicator-st1010-25-vials-box-by-medicom","provider":"Unique Dental Supply Inc.","version":"1.0","type":"link"}